
Cosmetics & personal care · General methods
Hair dye analysis
Product composition and safety assessment. Report built on the official document(s) shown below: record the method, quality controls, method-specific findings and result. Validate the method in your own laboratory and follow local regulations.
Guideline: Official basis: Regulation (EC) No 1223/2009 (Cosmetic products); ISO 22716 (Cosmetics GMP); ISO 17516 / ISO 21149 (Cosmetics microbiology). Analytical identification of a cosmetic colourant is different from using it as a laboratory stain. Use a substance and product specific validated method.
Demo reporting — nothing is saved. Sign in to store cases in your lab database.
Choose industry & category
Choose stain protocol
Tip: tap the small mic next to any box title and speak to fill just that box. Industry-specific sample fields appear at the top of the findings form; add or delete them from My Dashboard.
Sample & client
Sample details
Cosmetics & personal care · General methods
Hair dye analysis
Official basis: Regulation (EC) No 1223/2009 (Cosmetic products); ISO 22716 (Cosmetics GMP); ISO 17516 / ISO 21149 (Cosmetics microbiology). Analytical identification of a cosmetic colourant is different from using it as a laboratory stain. Use a substance and product specific validated method.
Speak patient details or findings, e.g. "patient name Ravi Kumar, age 45, mobile 98765 43210, qc: certified calibrators, blanks, matrix spikes and recovery controls not run". Or tap the small mic beside any box to fill only that box, then tap the next box's mic. Your browser asks for the microphone only once. Sign in as lab staff for AI understanding; here simple word matching is used.
Fill from microscope photo
Hold the phone camera to the eyepiece, use a microscope camera, or upload an image. AI suggests findings; nothing is filled until you tick and accept. Photograph only the smear - no patient labels.
Sign in as lab staff to useSample & client details
Method & quality control
Cosmetic product test record
Hair dye composition (Reg. (EC) 1223/2009 Annex III)
Observations
Result
AI differential interpretation
Use AI interpretation in the lab workspace (staff sign-in)Reads the findings you typed, spoke or filled from microscope photos. Decision support only - the verifying pathologist / microbiologist decides.
Finished reviewing the findings?
Smear Camera — teach STAINIC to read Hair dye analysis
Snap the smear, film or microscope field with your phone camera, or upload a microscope camera image. Photos help STAINIC learn stain patterns so it can suggest findings in future.
Mobile data / Wi-Fi
Each photo (1-12 MB) is uploaded over your internet connection. On mobile data this uses your data plan and may incur charges; prefer Wi-Fi for many photos.
How AI will use photos
Photos are kept in a separate STAINIC image library (not your storage quota) to build future recognition models. When you tap "Suggest findings", the photo is also sent to an AI model, over the internet, which proposes values; nothing is filled until you tick and accept them.
Disclaimer
Photograph only the smear / film / field — never patient names, labels, faces or documents. Photos are not linked to any patient. AI suggestions are decision-support only and must always be verified by a qualified pathologist; they are not a diagnosis or treatment advice.
