Reagents & materials
Dye penetration in nonporous package seals - Reagents & Materials
What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).
Packaging & container integrity · General
Dye penetration in nonporous package seals
Location of leaks in flexible nonporous packaging
Reagents & stains
| Item | Amount per test | Procure |
|---|---|---|
| F3039-compatible aqueous dye penetrant with the prescribed wetting systemPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Use a formulation qualified for nonporous seal testingPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Kits
| Item | Amount per test | Procure |
|---|---|---|
| Optional F3039 Method-A seal-leak reagent/application setPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Consumables & materials
| Item | Amount per test | Procure |
|---|---|---|
| Nonporous flexible packages or edge-seal samplesPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Appropriate dye dispenserPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Clean inspection backgroundPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Compatible traysPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Waste suppliesPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Equipment
| Item | Amount per test | Procure |
|---|---|---|
| Visible inspection with suitable magnification if requiredPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| TimingPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Specimen-conditioning equipmentPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Controls & reference materials
| Item | Amount per test | Procure |
|---|---|---|
| Known intact packagePer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Reference seal-channel defectPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Reagent/backgroundPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Wetting-performance checksPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Official basis (Method): ASTM F3039-23 Method A addresses package-edge seals. It is destructive and qualitative; detection does not quantify a leak rate.
Procurement note: This row is Method A for seals. The full standard controls dye composition and test geometry; a porous-medical-package product is not automatically qualified.
Sources:G113 ASTM International
Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.