Reagents & materials
Methylene blue formation - Reagents & Materials
What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).
Environmental water wastewater & soil testing · General
Methylene blue formation
Sulfide determination in water
Reagents & stains
| Item | Amount per test | Procure |
|---|---|---|
| N-dimethyl-p-phenylenediamine colour reagentPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Ferric-chloride reagentPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Specified acidic mediumPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Sulfide standardPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Sample-preservation reagents where requiredPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Kits
| Item | Amount per test | Procure |
|---|---|---|
| Optional method-compatible methylene-blue sulfide reagent setPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Consumables & materials
| Item | Amount per test | Procure |
|---|---|---|
| Matched cells/cuvettesPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Closed sample vesselsPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| PipettesPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Compatible chemical-waste containersPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Equipment
| Item | Amount per test | Procure |
|---|---|---|
| Spectrophotometer/colorimeterPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Calibrated pipettesPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Chemical ventilationPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Controls & reference materials
| Item | Amount per test | Procure |
|---|---|---|
| Sulfide calibration/check standardPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Reagent blankPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Matrix controlPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Official basis (Method): EPA 376.2 is a separate colorimetric sulfide method. It must not be confused with MBAS surfactant testing despite the shared colour name.
Procurement note: Methylene blue is generated by the colour reaction. Purchasing methylene-blue stain alone does not supply the sulfide assay.
Sources:G131 US EPA
Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.