Reagents & materials

Chlorophyll fluorescence - Reagents & Materials

What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).

Back to Chlorophyll fluorescence

Environmental water wastewater & soil testing · General

Chlorophyll fluorescence

Algal pigment concentration

Reagents & stains

ItemProcure
Acetone of the specified grade, reagent water, chlorophyll-a standard and acidification reagent if pheophytin correction is used. No added fluorescent stainPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Kits

ItemProcure
Optional chlorophyll calibration standardsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
No stain kit requiredPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Consumables & materials

ItemProcure
Glass-fibre filtersPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Filtration assembliesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Extraction tubesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Fluorometer cuvettesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Dark storage containersPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Equipment

ItemProcure
Calibrated fluorometerPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Filtration apparatusPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Tissue grinder or validated extraction equipmentPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
CentrifugePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Temperature-controlled storagePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Controls & reference materials

ItemProcure
Chlorophyll calibration standardPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Extraction blankPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Method QC samplesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Official basis (Method): EPA Method 445.0 measures chlorophyll a and pheophytin a fluorescence. It does not enumerate species or demonstrate toxin production, and uses intrinsic pigment rather than a stain.

Procurement note: EPA 445.0 is pigment extraction/fluorometry. Instrument/filter configurations and acidification option must match the controlled method.

Sources:G126 US EPA

Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.

Guideline-backed stain reporting for every laboratory.

Privacy, terms & disclaimers
Privacy

Patient data entered in demo pages stays in your browser and is never stored. Data saved in the signed-in workspace is kept in your laboratory's secured database, visible only to approved staff of that hospital by role; researchers see anonymised records only. The microphone is never on in the background: a box mic switches on only when you tap it, shows a red 'Listening' badge and turns itself off within 12 seconds; hands-free Voice Commands stay on only while their red switch is on and turn off after 30 seconds of silence. Speech is converted to text by your phone or browser's speech service; for signed-in staff, when that is unclear, the short clip for that one box is sent to an AI speech model to be understood and is not stored by STAINIC. Microscope photos sent for AI suggestions must show only the smear, never patient identifiers. We do not sell or share personal data.

Terms of Use

STAINIC is provided to authorised laboratory professionals. You are responsible for the accuracy of entries - including anything filled by voice, OCR or AI - for keeping your login private, for sharing report links and PINs only with the patient or treating doctor, and for complying with your institution's policies and local health-data laws. Access may be revoked for misuse.

Medical & Educational Disclaimer

Guideline content, scores, pattern hints, auto-drafted impressions and AI suggestions from voice or microscope photos are decision-support and educational aids. They can be wrong and do not replace the professional judgement of a qualified pathologist or microbiologist, who must review and sign every report.

No Treatment Advice