Reagents & materials

Osmium tetroxide, ruthenium tetroxide and phosphotungstic acid - Reagents & Materials

What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).

Back to OsO4 / RuO4 / PTA (EM)

Materials science electronics & nondestructive testing · General

Osmium tetroxide, ruthenium tetroxide and phosphotungstic acid

Polymer electron-microscopy contrast

Reagents & stains

ItemProcure
Supplied osmium tetroxide solutionPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Supplied ruthenium tetroxide solutionPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
OR phosphotungstic acid reagent. Carrier/embedding medium must be selected for the polymer and routePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Kits

ItemProcure
Optional sealed EM contrast reagent ampoulesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
No combined Os/Ru/PTA kit or on-site generation is assumedPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Consumables & materials

ItemProcure
Polymer blocks/sectionsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Compatible sealed staining vesselsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
TEM grids or SEM mounts as appropriatePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
KnivesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Embedding suppliesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Equipment

ItemProcure
Ultramicrotome or other validated section preparationPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
TEM or suitable SEMPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Dedicated extracted enclosure for volatile metal oxidantsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Controls & reference materials

ItemProcure
Unstained sectionPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Known polymer phase referencePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Carrier/embedding blankPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Imaging calibrationPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Official basis (Research): Research or material-specific contrast methods. No universal official stain protocol is assigned.

Procurement note: OsO4/RuO4 and PTA are distinct alternatives. Volatile oxidants require compatible sealed handling, chemical protection and dedicated metal-containing waste; supplier guidance does not validate every polymer.

Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.

Guideline-backed stain reporting for every laboratory.

Privacy, terms & disclaimers
Privacy

Patient data entered in demo pages stays in your browser and is never stored. Data saved in the signed-in workspace is kept in your laboratory's secured database, visible only to approved staff of that hospital by role; researchers see anonymised records only. The microphone is never on in the background: a box mic switches on only when you tap it, shows a red 'Listening' badge and turns itself off within 12 seconds; hands-free Voice Commands stay on only while their red switch is on and turn off after 30 seconds of silence. Speech is converted to text by your phone or browser's speech service; for signed-in staff, when that is unclear, the short clip for that one box is sent to an AI speech model to be understood and is not stored by STAINIC. Microscope photos sent for AI suggestions must show only the smear, never patient identifiers. We do not sell or share personal data.

Terms of Use

STAINIC is provided to authorised laboratory professionals. You are responsible for the accuracy of entries - including anything filled by voice, OCR or AI - for keeping your login private, for sharing report links and PINs only with the patient or treating doctor, and for complying with your institution's policies and local health-data laws. Access may be revoked for misuse.

Medical & Educational Disclaimer

Guideline content, scores, pattern hints, auto-drafted impressions and AI suggestions from voice or microscope photos are decision-support and educational aids. They can be wrong and do not replace the professional judgement of a qualified pathologist or microbiologist, who must review and sign every report.

No Treatment Advice

STAINIC is a laboratory reporting tool, not a treatment website. It does not diagnose, prescribe or recommend therapy to patients. Patients should discuss results with their treating doctor.

Legal

Stain grading follows published standards (CLSI, WHO, NTEP, ICSH, Bethesda, CAP) and remains the property of their authors. OCR is approximate and must be checked. Provided "as is" without warranty; liability is limited to the extent permitted by law.

© 2026 Stainic.com. A Madomic Kalin Company. AI output is decision support only.

Diagnostic Laboratory Stains Management · www.stainic.com