Reagents & materials

Direct blue, acid fuchsin and chlorazol black E - Reagents & Materials

What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).

Back to Mycorrhiza Root Stains

Plant health seed testing & plant research · General

Direct blue, acid fuchsin and chlorazol black E

Mycorrhizal root colonisation

Reagents & stains

ItemProcure
Direct blue, acid fuchsin or chlorazol black E. KOH clearing reagent, HCl, glycerol, lactic acid and waterPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Bleaching reagent only if the validated method requires itPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Kits

ItemProcure
Individual ready-to-use mycorrhizal stain/clearing reagents may be usedPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
No kit requiredPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Consumables & materials

ItemProcure
Fine-perforation tissue cassettesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Root containersPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
SlidesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
CoverslipsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
ForcepsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Equipment

ItemProcure
Brightfield/stereo microscopePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Laboratory hotplate or approved heating apparatusPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Chemical extraction ventilationPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Controls & reference materials

ItemProcure
Reference colonised root slidePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Noncolonised root materialPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Official basis (Research): INVAM documents these stains for root preparations. This is an institutional research procedure; the scoring approach must be stated separately.

Procurement note: Stains are alternatives. Listed constituents follow the INVAM research method; laboratory batch and matrix suitability still require verification.

Sources:G062 INVAM University of Kansas

Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.

Guideline-backed stain reporting for every laboratory.

Privacy, terms & disclaimers
Privacy

Patient data entered in demo pages stays in your browser and is never stored. Data saved in the signed-in workspace is kept in your laboratory's secured database, visible only to approved staff of that hospital by role; researchers see anonymised records only. The microphone is never on in the background: a box mic switches on only when you tap it, shows a red 'Listening' badge and turns itself off within 12 seconds; hands-free Voice Commands stay on only while their red switch is on and turn off after 30 seconds of silence. Speech is converted to text by your phone or browser's speech service; for signed-in staff, when that is unclear, the short clip for that one box is sent to an AI speech model to be understood and is not stored by STAINIC. Microscope photos sent for AI suggestions must show only the smear, never patient identifiers. We do not sell or share personal data.

Terms of Use

STAINIC is provided to authorised laboratory professionals. You are responsible for the accuracy of entries - including anything filled by voice, OCR or AI - for keeping your login private, for sharing report links and PINs only with the patient or treating doctor, and for complying with your institution's policies and local health-data laws. Access may be revoked for misuse.

Medical & Educational Disclaimer

Guideline content, scores, pattern hints, auto-drafted impressions and AI suggestions from voice or microscope photos are decision-support and educational aids. They can be wrong and do not replace the professional judgement of a qualified pathologist or microbiologist, who must review and sign every report.

No Treatment Advice

STAINIC is a laboratory reporting tool, not a treatment website. It does not diagnose, prescribe or recommend therapy to patients. Patients should discuss results with their treating doctor.

Legal

Stain grading follows published standards (CLSI, WHO, NTEP, ICSH, Bethesda, CAP) and remains the property of their authors. OCR is approximate and must be checked. Provided "as is" without warranty; liability is limited to the extent permitted by law.

© 2026 Stainic.com. A Madomic Kalin Company. AI output is decision support only.

Diagnostic Laboratory Stains Management · www.stainic.com