Reagents & materials

Bone Marrow Aspirate - Myelogram & M:E Ratio (ICSH) - Reagents & Materials

What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).

Back to Bone Marrow Aspirate

Human (Clinical) · Haematology and transfusion

Wright, Wright-Giemsa, May-Grünwald-Giemsa, Leishman and Diff-Quik

Blood and marrow cellular morphology

Reagents & stains

ItemProcure
Wright/Wright-GiemsaPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
MGGPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
LeishmanPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Rapid Romanowsky setPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Matched buffer/fixation reagentPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Immersion oilPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Kits

ItemProcure
Optional selected Romanowsky setPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Rapid variants have separate eosin/thiazine solutionsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Consumables & materials

ItemProcure
Glass slidesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Labelled slide boxesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Transfer pipettesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Stain jars/racksPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Coverslips if specifiedPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Equipment

ItemProcure
Brightfield microscopePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
PipettesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
TimerPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Staining stationPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Optional validated blood-film stainerPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Controls & reference materials

ItemProcure
Fixed blood/marrow reference filmsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Stain-lot referencePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Official basis (Guidance): CLSI H20 third edition 2026 addresses reference differential counting; ICSH 2026 supports validated Romanowsky marrow stains. Classification systems do not replace staining SOPs.

Procurement note: Formulations have distinct buffer/fixation requirements. Reporting/counting guidance does not prescribe a single kit.

Sources:G025 CLSIG026 International Council for Standardization in Haematology

Human (Clinical) · Haematology and transfusion

Perls Prussian blue

Marrow iron and siderotic granules

Reagents & stains

ItemProcure
Potassium-ferrocyanide iron reagentPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Matched acidPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Nuclear-red counterstainPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Compatible fixation/mountantPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Kits

ItemProcure
Optional Perls/Prussian-blue setPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Consumables & materials

ItemProcure
Adhesive slidesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
CoverslipsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Tissue cassettes or prepared sectionsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Staining vesselsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Equipment

ItemProcure
Microtome/tissue-processing access or prepared sectionsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Brightfield microscopePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Staining stationPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Chemical ventilationPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Controls & reference materials

ItemProcure
Known iron-positive/negative control sections or filmsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Official basis (Guidance): ICSH 2026 supports Perls reaction. Name the chosen storage iron scale; ring sideroblast quantification is a different assessment.

Procurement note: Documented iron-stain components. Counterstain variants and tissue versus marrow-film preparation differ.

Sources:G026 International Council for Standardization in Haematology

Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.

Guideline-backed stain reporting for every laboratory.

Privacy, terms & disclaimers
Privacy

Patient, client and sample data entered in demo pages stays in your browser and is never stored. Data saved in the signed-in workspace is kept in your laboratory's secured database, visible only to approved staff of that organisation by role; researchers see anonymised records only. The microphone is never on in the background: a box mic switches on only when you tap it, shows a red 'Listening' badge and turns itself off within 12 seconds; hands-free Voice Commands stay on only while their red switch is on and turn off after 30 seconds of silence. Speech is converted to text by your phone or browser's speech service; for signed-in staff, when that is unclear, the short clip for that one box is sent to an AI speech model to be understood and is not stored by STAINIC. Microscope photos sent for AI suggestions must show only the smear or specimen, never patient or client identifiers. Supplier link clicks are counted by country only, without personal details. We do not sell or share personal data.

Terms of Use

STAINIC is provided to authorised laboratory professionals in clinical, veterinary, industrial, environmental, forensic and research laboratories. You are responsible for the accuracy of entries - including anything filled by voice, OCR or AI - for keeping your login private, for sharing report links and PINs only with the patient, client or treating doctor, and for complying with your institution's policies, accreditation requirements and local data-protection laws. Access may be revoked for misuse.

Medical & Professional Disclaimer

Guideline content, scores, pattern hints, auto-drafted impressions and AI suggestions from voice or microscope photos are decision-support and educational aids. They can be wrong and do not replace the professional judgement of a qualified pathologist, microbiologist, veterinarian, analyst or examiner, who must review and sign every report.

No Treatment Advice

STAINIC is a laboratory reporting tool, not a treatment website. It does not diagnose, prescribe or recommend therapy to patients. Patients should discuss results with their treating doctor.

Standards & References

Each industry (non-human) method form shows an 'Official' badge with the document it follows (e.g. ISO, ASTM, OECD, ISTA, WOAH, EPPO, pharmacopoeias, EU regulations) or a 'Best practice' badge with a caution where no single official procedure was found. STAINIC summarises the reporting elements only; it does not reproduce, replace or certify compliance with those documents. Always use the current edition, the manufacturer's instructions for use and your validated SOP, and check local regulatory limits.

Supplier Links

Reagent and supplier links are provided for convenience. Ranking and badges reflect STAINIC's editorial assessment and partnerships, not regulatory approval or a guarantee of product quality, price or availability. Verify product suitability, certificates and local registration with the seller.

Legal

Stain grading follows published standards (CLSI, WHO, NTEP, ICSH, Bethesda, CAP, ISO, ASTM, OECD and others) that remain the property of their authors and publishers. OCR is approximate and must be checked. Provided "as is" without warranty; liability is limited to the extent permitted by law.

© 2026 Stainic.com. A Madomic Kalin Company. AI output is decision support only.