Reagents & materials

DPD colour reaction - Reagents & Materials

What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).

Back to DPD colour reaction

Environmental water wastewater & soil testing · General

DPD colour reaction

Total residual chlorine in water

Reagents & stains

ItemProcure
DPD total-chlorine indicator system with bufferPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Iodide as specifiedPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Reagent waterPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Chlorine verification standardPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Kits

ItemProcure
Optional method-compatible DPD total-chlorine powderPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Tablet or liquid reagent setPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Consumables & materials

ItemProcure
Clean matched sample cellsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
PipettesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
CapsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Sample vesselsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Equipment

ItemProcure
Compatible colorimeter/spectrophotometer or authorised comparatorPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Calibrated dispenserPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Controls & reference materials

ItemProcure
Reagent blankPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Method-compatible chlorine calibration/verification materialPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Official basis (Method): EPA 330.5 is a named DPD spectrophotometric method. Apply the method's matrix and reporting limits and the applicable compliance programme.

Procurement note: Order total-chlorine chemistry. A free-chlorine DPD product alone may not include the reagents required for total residual chlorine.

Sources:G130 US EPA

Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.

STAINIC logo
STAINIC
Stains Made Scenic

Diagnostic Laboratory Stains Management · www.stainic.com

Privacy

Patient data entered in demo pages stays in your browser and is never stored. Data saved in the signed-in workspace is kept in your laboratory's secured database, visible only to approved staff of that hospital by role; researchers see anonymised records only. The microphone is never on in the background: a box mic switches on only when you tap it, shows a red 'Listening' badge and turns itself off within 12 seconds; hands-free Voice Commands stay on only while their red switch is on and turn off after 30 seconds of silence. Speech is converted to text by your phone or browser's speech service; for signed-in staff, when that is unclear, the short clip for that one box is sent to an AI speech model to be understood and is not stored by STAINIC. Microscope photos sent for AI suggestions must show only the smear, never patient identifiers. We do not sell or share personal data.

Terms of Use

STAINIC is provided to authorised laboratory professionals. You are responsible for the accuracy of entries - including anything filled by voice, OCR or AI - for keeping your login private, for sharing report links and PINs only with the patient or treating doctor, and for complying with your institution's policies and local health-data laws. Access may be revoked for misuse.

Medical & Educational Disclaimer

Guideline content, scores, pattern hints, auto-drafted impressions and AI suggestions from voice or microscope photos are decision-support and educational aids. They can be wrong and do not replace the professional judgement of a qualified pathologist or microbiologist, who must review and sign every report.

No Treatment Advice

STAINIC is a laboratory reporting tool, not a treatment website. It does not diagnose, prescribe or recommend therapy to patients. Patients should discuss results with their treating doctor.

Legal

Stain grading follows published standards (CLSI, WHO, NTEP, ICSH, Bethesda, CAP) and remains the property of their authors. OCR is approximate and must be checked. Provided "as is" without warranty; liability is limited to the extent permitted by law.

© 2026. Stainic.com. A Madomic Kalin Company