Reagents & materials

Sodium rhodizonate and dithiooxamide - Reagents & Materials

What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).

Back to Sodium Rhodizonate Test

Forensic science & legal investigation · General

Sodium rhodizonate and dithiooxamide

Lead and copper residue visualisation

Reagents & stains

ItemProcure
Sodium rhodizonatePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Sodium bitartrate/tartaric-acid bufferPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Hydrochloric-acid reagent. Copper route: dithiooxamidePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
EthanolPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Ammonium-hydroxide reagentPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Purified water. Keep routes separatePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Kits

ItemProcure
Optional method-specific lead-residue or copper-residue reagent packPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
No SEM–EDS kit is impliedPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Consumables & materials

ItemProcure
White filter paperPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
SwabsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Dropper/spray bottlesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Suitable evidence supportsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Photographic scalesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Equipment

ItemProcure
Extracted chemical workstationPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Visible-light examination/cameraPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Appropriate liquid handlingPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Protected reagent storagePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Controls & reference materials

ItemProcure
Known lead control for rhodizonatePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Known copper control for DTOPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Separate clean-substrate/reagent negativesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Official basis (Guidance): NIJ training describes chemical residue tests. ASTM E1588 instead concerns SEM-EDS particle analysis and is not the procedure for these spot tests.

Procurement note: NIJ explicitly lists core chemicals/media. Archived guidance still needs a current casework SOP; ASTME1588 equipment is not the basis for these spot tests.

Sources:G078 US National Institute of JusticeG079 NIST OSAC and ASTM

Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.

STAINIC logo
STAINIC
Stains Made Scenic

Diagnostic Laboratory Stains Management · www.stainic.com

Privacy

Patient data entered in demo pages stays in your browser and is never stored. Data saved in the signed-in workspace is kept in your laboratory's secured database, visible only to approved staff of that hospital by role; researchers see anonymised records only. The microphone is never on in the background: a box mic switches on only when you tap it, shows a red 'Listening' badge and turns itself off within 12 seconds; hands-free Voice Commands stay on only while their red switch is on and turn off after 30 seconds of silence. Speech is converted to text by your phone or browser's speech service; for signed-in staff, when that is unclear, the short clip for that one box is sent to an AI speech model to be understood and is not stored by STAINIC. Microscope photos sent for AI suggestions must show only the smear, never patient identifiers. We do not sell or share personal data.

Terms of Use

STAINIC is provided to authorised laboratory professionals. You are responsible for the accuracy of entries - including anything filled by voice, OCR or AI - for keeping your login private, for sharing report links and PINs only with the patient or treating doctor, and for complying with your institution's policies and local health-data laws. Access may be revoked for misuse.

Medical & Educational Disclaimer

Guideline content, scores, pattern hints, auto-drafted impressions and AI suggestions from voice or microscope photos are decision-support and educational aids. They can be wrong and do not replace the professional judgement of a qualified pathologist or microbiologist, who must review and sign every report.

No Treatment Advice

STAINIC is a laboratory reporting tool, not a treatment website. It does not diagnose, prescribe or recommend therapy to patients. Patients should discuss results with their treating doctor.

Legal

Stain grading follows published standards (CLSI, WHO, NTEP, ICSH, Bethesda, CAP) and remains the property of their authors. OCR is approximate and must be checked. Provided "as is" without warranty; liability is limited to the extent permitted by law.

© 2026. Stainic.com. A Madomic Kalin Company