Reagents & materials

CR-39 alkaline track etching - Reagents & Materials

What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).

Back to CR-39 alkaline track etching

Materials science electronics & nondestructive testing · General

CR-39 alkaline track etching

Passive radiation measurement

Reagents & stains

ItemProcure
CR-39/PADC detector materialPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Method-specified alkaline etchantPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Commonly sodium hydroxidePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Purified rinse water. No dye is requiredPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Kits

ItemProcure
Optional calibrated radon detectorPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Accredited/qualified readout-service packagePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
In-house processing is a separate capabilityPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Consumables & materials

ItemProcure
Passive diffusion housingsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Detector holdersPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Tracking labelsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Clean transport/storage packagingPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Alkali-compatible vesselsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Equipment

ItemProcure
Controlled etch bathPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Temperature measurementPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Calibrated optical track-counting system or external readout servicePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Caustic containmentPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Controls & reference materials

ItemProcure
Unexposed detector blanksPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Certified exposure/calibration setPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Duplicate detectorsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Track-countingPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Batch controlsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Official basis (Framework): Related contrast technique, not staining. ISO 11665-4:2021 concerns integrated radon measurement; it is not blanket authority for neutron dosimetry.

Procurement note: Typical radon-system supplies, not a neutron dosimetry specification. Detector geometry, batch calibration and processing system must be qualified together.

Sources:G074 ISO

Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.

STAINIC logo
STAINIC
Stains Made Scenic

Diagnostic Laboratory Stains Management · www.stainic.com

Privacy

Patient data entered in demo pages stays in your browser and is never stored. Data saved in the signed-in workspace is kept in your laboratory's secured database, visible only to approved staff of that hospital by role; researchers see anonymised records only. The microphone is never on in the background: a box mic switches on only when you tap it, shows a red 'Listening' badge and turns itself off within 12 seconds; hands-free Voice Commands stay on only while their red switch is on and turn off after 30 seconds of silence. Speech is converted to text by your phone or browser's speech service; for signed-in staff, when that is unclear, the short clip for that one box is sent to an AI speech model to be understood and is not stored by STAINIC. Microscope photos sent for AI suggestions must show only the smear, never patient identifiers. We do not sell or share personal data.

Terms of Use

STAINIC is provided to authorised laboratory professionals. You are responsible for the accuracy of entries - including anything filled by voice, OCR or AI - for keeping your login private, for sharing report links and PINs only with the patient or treating doctor, and for complying with your institution's policies and local health-data laws. Access may be revoked for misuse.

Medical & Educational Disclaimer

Guideline content, scores, pattern hints, auto-drafted impressions and AI suggestions from voice or microscope photos are decision-support and educational aids. They can be wrong and do not replace the professional judgement of a qualified pathologist or microbiologist, who must review and sign every report.

No Treatment Advice

STAINIC is a laboratory reporting tool, not a treatment website. It does not diagnose, prescribe or recommend therapy to patients. Patients should discuss results with their treating doctor.

Legal

Stain grading follows published standards (CLSI, WHO, NTEP, ICSH, Bethesda, CAP) and remains the property of their authors. OCR is approximate and must be checked. Provided "as is" without warranty; liability is limited to the extent permitted by law.

© 2026. Stainic.com. A Madomic Kalin Company